WeChat Mini Program
Old Version Features

Current Design Status of High Energy Beam Transfer Line for KHIMA Project

Journal of the Korean Physical Society(2013)

Division of Heavy Ion Accelerator

Cited 7|Views37
Abstract
The Korea heavy ion medical accelerator (KHIMA) project is developing and constructing the heavy ion medical accelerator for the first time in Korea since 2010. This paper describes the status of high energy beam transfer line (HEBT), which connects the superconducting cyclotron to the treatment rooms. The HEBT provides a patient with 145–430 MeV/u carbon (12C6+) beam to cure cancer. The HEBT is consisted of 6 beam lines (4 horizontal, 1 vertical and 1 oblique). The size of the design HEBT is 41 m in length, 11 m in width and 17 m in height. Total number of magnets is 53 for focusing magnets and 22 for bending magnets. In the description, the current design status of the HEBT is described.
More
Translated text
Key words
KIRAMS,KHIMA,Hadron therapy,Carbon therapy,Cyclotron,Beam line,Beam optics
PDF
Bibtex
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Data Disclaimer
The page data are from open Internet sources, cooperative publishers and automatic analysis results through AI technology. We do not make any commitments and guarantees for the validity, accuracy, correctness, reliability, completeness and timeliness of the page data. If you have any questions, please contact us by email: report@aminer.cn