Chrome Extension
WeChat Mini Program
Use on ChatGLM

In-Source Decay and Pseudo-MS3 of Peptide and Protein Ions Using Liquid AP-MALDI

Journal of the American Society for Mass Spectrometry(2016)SCI 3区SCI 2区

Fondazione Pisana per la Scienza ONLUS

Cited 13|Views23
Abstract
Atmospheric pressure MALDI on a Q-Exactive instrument was optimized for in-source decay and pseudo-MS3. The dependence of AP-MALDI ISD on the MALDI liquid matrix was investigated for peptides and proteins. The liquid matrices enabled long-life ISD signal, and exhibited high fragment ion yield and signal stability. Extensive a-, b-, c-, y-, and z-type fragment series were observed depending on the matrix used but were most extensive with 2,5-DHB. Complete sequence coverage of small peptide and intact protein-terminus sequence tags were obtained and confirmed using HCD as a pseudo-MS3 method. Graphical Abstract ᅟ.
More
Translated text
Key words
MALDI,In-source decay,MS/MS,Pseudo MS3,T3 sequencing
PDF
Bibtex
AI Read Science
AI Summary
AI Summary is the key point extracted automatically understanding the full text of the paper, including the background, methods, results, conclusions, icons and other key content, so that you can get the outline of the paper at a glance.
Example
Background
Key content
Introduction
Methods
Results
Related work
Fund
Key content
  • Pretraining has recently greatly promoted the development of natural language processing (NLP)
  • We show that M6 outperforms the baselines in multimodal downstream tasks, and the large M6 with 10 parameters can reach a better performance
  • We propose a method called M6 that is able to process information of multiple modalities and perform both single-modal and cross-modal understanding and generation
  • The model is scaled to large model with 10 billion parameters with sophisticated deployment, and the 10 -parameter M6-large is the largest pretrained model in Chinese
  • Experimental results show that our proposed M6 outperforms the baseline in a number of downstream tasks concerning both single modality and multiple modalities We will continue the pretraining of extremely large models by increasing data to explore the limit of its performance
Try using models to generate summary,it takes about 60s
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Related Papers
Data Disclaimer
The page data are from open Internet sources, cooperative publishers and automatic analysis results through AI technology. We do not make any commitments and guarantees for the validity, accuracy, correctness, reliability, completeness and timeliness of the page data. If you have any questions, please contact us by email: report@aminer.cn
Chat Paper

要点】:本文研究了在Q-Exactive仪器上使用大气压MALDI技术进行肽和蛋白质离子的源内衰变(ISD)和伪MS3,证明了液体基质在提高ISD信号寿命、片段离子产率和信号稳定性方面的作用,并实现了小肽和完整蛋白质末端序列标签的完整序列覆盖。

方法】:通过优化大气压MALDI技术在Q-Exactive仪器上的参数,研究了不同液体基质对肽和蛋白质ISD的影响。

实验】:实验在Q-Exactive仪器上完成,使用液体基质进行了ISD和伪MS3分析,观察了不同类型的片段离子系列,特别是在使用2,5-DHB基质时,实现了广泛的片段离子系列,并通过HCD作为伪MS3方法确认了小肽和完整蛋白质末端序列标签的序列覆盖。