Compact Readout of Large CLYC Scintillators with Silicon Photomultipler Arrays

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT(2020)

Arizona State Univ | Los Alamos Natl Lab

Cited 13|Views22
Abstract
Compact readout of a large (5×5×5 cm3) CLYC scintillator was demonstrated with a 8×8 array of 6mm silicon photomultipliers (SiPMs, specifically, a SensL ArrayJ-60035-64P) and an optimized amplification and summing circuit. Read out by the SiPM array, the crystal yielded an energy resolution of 5.5% at 662 keV and a figure of merit of 3.5, equivalent to the performance achieved with a 3-inch Hamamatsu R6233-100 PMT. To reduce channel count and avoid individual amplification of each SiPM in the array, the standard outputs of 16 SiPMs were passively summed then amplified. A current feedback amplifier was used for each channel to provide the required fast response time. The four amplified channels were then passively summed resulting in a single signal channel. A custom laboratory setup, based on the PSD8C ASIC, was used to capture the output and provide time-gated integration for PSD computation. The compact volume, low bias voltage, and reduced mass of the SiPM array readout are desirable for space and national security applications.
More
Translated text
Key words
CLYC,Silicon photomultipliers,Readout electronics
PDF
Bibtex
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Related Papers

Characterization of 1-Inch CLYC Scintillator Coupled with 8 × 8 SiPM Array

Tuchen Huang, Zhibo Zhang
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 2021

被引用13

n/? discrimination of SiPM array-based CLYC detector

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2022

被引用7

PSD Performance of EJ-276 and EJ-301 Scintillator Readout with SiPM Array

Nuclear instruments and methods in physics research Section A, Accelerators, spectrometers, detectors and associated equipment/Nuclear instruments & methods in physics research Section A, Accelerators, spectrometers, detectors and associated equipment 2022

被引用5

Advancements of the Nspec System

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 2023

被引用5

Development of a Compact Fast-Neutron Spectrometer for Nuclear Emergency Response Applications

J. F. Perello,T. H. Shin,T. Cutler,K. D. Bartlett, C. Bates, D. Beckman,T. C. Borgwardt, D. Hemsing, D. Mercer,K. Smith
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 2023

被引用2

Optimization of Fast Output from SiPM Array for Pulse Shape Discrimination Techniques at High Counting Rates

Yi Guo, Yulian Zhang,Yipan Guo,Meihua Fang,Zhiyong Wei,Can Cheng,Wenbao Jia, Mengmeng Wang, Jiafeng Li, Ming Zhang, Xinyi Cai
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 2024

被引用0

Data Disclaimer
The page data are from open Internet sources, cooperative publishers and automatic analysis results through AI technology. We do not make any commitments and guarantees for the validity, accuracy, correctness, reliability, completeness and timeliness of the page data. If you have any questions, please contact us by email: report@aminer.cn
Chat Paper

要点】:该论文展示了如何使用硅光电倍增管(SiPMs)阵列紧凑型读出5×5×5 cm3大小的CLYC闪烁体,其能量分辨率达到5.5%,性能相当于3英寸Hamamatsu R6233-100 PMT。

方法】:研究采用8×8阵列的6mm SiPMs(SensL ArrayJ-60035-64P)和优化的放大与求和电路进行读出,通过被动求和和放大SiPMs的标准输出以降低通道数和避免每个SiPM的单独放大。

实验】:实验使用PSD8C ASIC为基础的定制实验室装置捕获输出,提供时间门控积分以计算PSD。这种紧凑型读出方式具有体积小、偏置电压低和质量轻的特点,适合于航天和国家安全应用。