Conduction system pacing (CSP)-His bundle pacing (HBP) and left bundle branch area pacing (LBBAP)-are emerging alternatives to biventricular pacing (BVP) for cardiac resynchronization therapy (CRT) in heart failure. However, evidence is largely limited to small and observational studies. We conducted a meta-analysis including a total of 15 randomized controlled trials (RCTs) and non-RCTs that compare CSP (HBP and LBBAP) with BVP in patients with CRT indications. We assessed the mean differences in QRS duration (QRSd), pacing threshold, left ventricular ejection fraction (LVEF), and New York Heart Association (NYHA) class score. CSP resulted in a pooled mean QRSd improvement of -20.3 ms (95% confidence interval [CI] -26.1 to -14.5 ms; P < .05; I2= 87.1%) vs BVP. For LVEF, a weighted mean increase of 5.2% (95% CI 3.5%-6.9%; P < .05; I2 = 55.6) was observed after CSP vs BVP. The mean NYHA score was reduced by -0.40 (95% CI -0.6 to -0.2; P < .05; I2 = 61.7) after CSP vs BVP. A subgroup analysis of outcomes stratified by LBBAP and HBP demonstrated statistically significant weighted mean improvements of QRSd and LVEF with both CSP modalities compared with BVP. LBBAP resulted in NYHA improvement compared with BVP, without differences between CSP subgroups. LBBAP is associated with a significantly lowered mean pacing threshold of -0.51 V (95% CI -0.68 to -0.38 V) while HBP had increased the mean threshold (0.62 V; 95% CI -0.03 to 1.26 V) compared with BVP; however, this was associated with significant heterogeneity. Overall, both CSP techniques are feasible and effective CRT alternatives for heart failure. Further RCTs are needed to establish long-term efficacy and safety.
More
Translated text
Key words
Heart failure,Cardiac resynchronization therapy,Bi-ventricular pacing,Conduction system pacing,His bundle pacing,Left bundle branch pacing
求助PDF
上传PDF
Bibtex
AI Read Science
AI Summary
AI Summary is the key point extracted automatically understanding the full text of the paper, including the background, methods, results, conclusions, icons and other key content, so that you can get the outline of the paper at a glance.
Example
Background
Key content
Introduction
Methods
Results
Related work
Fund
Key content
  • Pretraining has recently greatly promoted the development of natural language processing (NLP)
  • We show that M6 outperforms the baselines in multimodal downstream tasks, and the large M6 with 10 parameters can reach a better performance
  • We propose a method called M6 that is able to process information of multiple modalities and perform both single-modal and cross-modal understanding and generation
  • The model is scaled to large model with 10 billion parameters with sophisticated deployment, and the 10 -parameter M6-large is the largest pretrained model in Chinese
  • Experimental results show that our proposed M6 outperforms the baseline in a number of downstream tasks concerning both single modality and multiple modalities We will continue the pretraining of extremely large models by increasing data to explore the limit of its performance
Upload PDF to Generate Summary
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Data Disclaimer
The page data are from open Internet sources, cooperative publishers and automatic analysis results through AI technology. We do not make any commitments and guarantees for the validity, accuracy, correctness, reliability, completeness and timeliness of the page data. If you have any questions, please contact us by email: report@aminer.cn
Chat Paper
Summary is being generated by the instructions you defined