Chrome Extension
WeChat Mini Program
Use on ChatGLM

Intraoperative Sensor Technology Quantifies Inter-Prosthesis Pressure for Predicting Lower Limb Alignment after Oxford Unicompartmental Knee Arthroplasty.

Frontiers in Bioengineering and Biotechnology(2023)SCI 3区SCI 2区

Peking Univ | China Japan Friendship Hosp

Cited 1|Views22
Abstract
Purpose: The aim of this study is to quantify inter-prosthetic pressures at different knee angles in Oxford unicompartmental knee arthroplasty (OUKA) and its correlation with postoperative lower limb alignment. Methods: This study included 101 patients (122 knees) who underwent OUKA from March 2022 to July 2022. The previously designed matrix flexible force sensor was used to measure the inter-prosthesis pressure of different knee joint angles during the UKA operation, and the force variation trend and gap balance difference were obtained. The correlation between inter-prosthesis pressure and postoperative lower limb alignment index including hip-knee-ankle angle (HKAA) and posterior tibial slope (PTS) was analyzed. The effect of PTS change (ΔPTS) on the inter-prosthesis pressure and the range of motion (ROM) of the knee joint was analyzed. Radiographic and short-term clinical outcomes of included patients were assessed. Results: The inter-prosthesis pressure of the different knee joint angles during the operation was not consistent. The mean inter-prosthesis pressure and gap balance difference were 73.68.28 ± 41.65N and 36.48 ± 20.58N. The inter-prosthesis pressure at 0° and 20° was positively correlated with postoperative HKAA (p < 0.001). ΔPTS was positively correlated with the pressure at the end of knee extension and negatively correlated with the pressure at the end of knee flexion (p < 0.001). The HKAA, ROM, degree of fixed knee flexion deformity, and knee society score of the included patients were significantly improved compared with those before the operation (p < 0.001). Conclusion: The inter-prosthesis pressure measured at the knee extension position can predict postoperative HKAA to some degree. Changes in PTS will affect the inter-prosthesis pressure at the end of flexion and end of knee extension, but this change is not related to the range of motion of the knee joint.
More
Translated text
Key words
Oxford unicompartmental knee arthroplasty (UKA),limb alignment,posterior tibial slope (PTS),pressure sensor,hip-knee-ankle angle (HKAA)
PDF
Bibtex
AI Read Science
AI Summary
AI Summary is the key point extracted automatically understanding the full text of the paper, including the background, methods, results, conclusions, icons and other key content, so that you can get the outline of the paper at a glance.
Example
Background
Key content
Introduction
Methods
Results
Related work
Fund
Key content
  • Pretraining has recently greatly promoted the development of natural language processing (NLP)
  • We show that M6 outperforms the baselines in multimodal downstream tasks, and the large M6 with 10 parameters can reach a better performance
  • We propose a method called M6 that is able to process information of multiple modalities and perform both single-modal and cross-modal understanding and generation
  • The model is scaled to large model with 10 billion parameters with sophisticated deployment, and the 10 -parameter M6-large is the largest pretrained model in Chinese
  • Experimental results show that our proposed M6 outperforms the baseline in a number of downstream tasks concerning both single modality and multiple modalities We will continue the pretraining of extremely large models by increasing data to explore the limit of its performance
Try using models to generate summary,it takes about 60s
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Data Disclaimer
The page data are from open Internet sources, cooperative publishers and automatic analysis results through AI technology. We do not make any commitments and guarantees for the validity, accuracy, correctness, reliability, completeness and timeliness of the page data. If you have any questions, please contact us by email: report@aminer.cn
Chat Paper

要点】:本研究通过术中传感器技术量化了牛津单间室膝关节置换术中不同膝关节角度间的假体压力,并探讨了其与术后下肢对线关系的关联性,为预测术后膝关节对线提供了一种新方法。

方法】:使用自定义的柔性力矩阵传感器测量101位患者在牛津单间室膝关节置换手术中不同膝关节角度的假体间压力,并分析这些压力与术后下肢对线指标如髋膝踝角(HKAA)和胫骨后倾角(PTS)的关系。

实验】:患者在2022年3月至2022年7月期间接受了手术,实验中收集的数据包括不同膝关节角度的假体压力和间隙平衡差异,并通过影像学评估和短期临床结果来评估手术效果。结果显示,术中不同膝关节角度的假体压力存在差异,且与术后的HKAA和PTS有显著相关性。胫骨后倾角变化(ΔPTS)与膝关节伸展末的压力呈正相关,与膝关节屈曲末的压力呈负相关。患者的HKAA、活动范围(ROM)、固定膝关节屈曲畸形程度和膝关节社会评分术后均有显著改善。