The Centiloid Scale: Guidance on Clinical Context of Use from the AMYPAD Consortium
Alzheimer's & Dementia(2024)
GE HealthCare
Abstract
AbstractBackgroundThe Centiloid method (CL) was introduced as a tracer‐independent measure for cortical amyloid load and is now commonly used in Alzheimer’s disease (AD) clinical trials. To facilitate its implementation into clinical settings, the AMYPAD consortium set out to integrate existing literature and recent work from the consortium to provide clinical context‐of‐use recommendations of the Centiloid scale, which has been submitted to the European Medicine Agency for endorsement as a Biomarker Qualification Opinion.MethodScreening of the literature was performed on the 7/11/23 on PubMed to identify articles mentioning “Centiloid”. The 159 results were reviewed to identify all cut‐offs established based on histopathology, visual reads, fluid biomarkers and cognition. Clinical trials inclusion criteria and amyloid clearance strategies were also included.ResultCompared to histopathology (gold standard), visual reads, and cerebrospinal fluid (clinical standards), Centiloid quantification accurately reflects the amount of AD pathology. With high certainty at the individual level, a CL value below 10 excludes the presence of Aβ pathology, while a value above 30 is a conservative estimate of amyloid‐positivity (Figure 1). Values falling in between these two cut‐offs (i.e., ‘gray‐zone’) are related to an increased risk of disease progression, but future studies enriched for this population are needed. The AMYPAD consortium additionally assessed the robustness and measurement uncertainty of the Centiloid scale and demonstrated that the method is highly robust against pipeline differences, such as processing space, target region, and reference region, though use of the pons could lead to increased bias and is not recommended. Measurement uncertainty was 3 to 8.3 CL across the total scale and is amyloid burden dependent.ConclusionFour clinical context‐of‐use for CL quantification are proposed: 1) adjunct to visual inspection methodology to achieve high certainty regarding the presence or absence of Aβ pathology, 2) a CL level of >30 could be utilised as a conservative cut‐off for the presence of Aβ pathology to guide the management of patients with objective cognitive impairment who may be eligible for anti‐amyloid disease‐modifying therapies, 3) support therapy monitoring and treatment decisions, 4) identification of emerging amyloid deposition and optimize risk‐stratification. Accounting for measurement uncertainty is essential when interpreting CL units.
MoreTranslated text
求助PDF
上传PDF
View via Publisher
AI Read Science
AI Summary
AI Summary is the key point extracted automatically understanding the full text of the paper, including the background, methods, results, conclusions, icons and other key content, so that you can get the outline of the paper at a glance.
Example
Background
Key content
Introduction
Methods
Results
Related work
Fund
Key content
- Pretraining has recently greatly promoted the development of natural language processing (NLP)
- We show that M6 outperforms the baselines in multimodal downstream tasks, and the large M6 with 10 parameters can reach a better performance
- We propose a method called M6 that is able to process information of multiple modalities and perform both single-modal and cross-modal understanding and generation
- The model is scaled to large model with 10 billion parameters with sophisticated deployment, and the 10 -parameter M6-large is the largest pretrained model in Chinese
- Experimental results show that our proposed M6 outperforms the baseline in a number of downstream tasks concerning both single modality and multiple modalities We will continue the pretraining of extremely large models by increasing data to explore the limit of its performance
Upload PDF to Generate Summary
Must-Reading Tree
Example

Generate MRT to find the research sequence of this paper
Data Disclaimer
The page data are from open Internet sources, cooperative publishers and automatic analysis results through AI technology. We do not make any commitments and guarantees for the validity, accuracy, correctness, reliability, completeness and timeliness of the page data. If you have any questions, please contact us by email: report@aminer.cn
Chat Paper
Summary is being generated by the instructions you defined